BRAND | Weka |
Product | 23614K-800-ANSI-2” |
Description | magnetic level indicator |
Internal code | IMP5023894 |
Weight | 25 |
Custom code | 902610 |
Technical specification | Standard Line 6 series Material bypass pipe 316/316L; 53x1.5m cap on top, blind flange on bottom, with G3/8" drain hole including plug Display rail: 38602E 316/PC for Tmax. +150°C, IP65 Red-silver aluminum plates Medium: oil/water, density 0.77 g/cm 3 Operating data Tmax. 90°C, Pmax. 4bar Connector spacing: L=800mm laterally. Connections: ANSI B16.5 2"/CLASS150/RF SF flanges Extras (included): - Manufacture of the VLI according to ATEX - Transmitter type 29710-R-NI-010-05-800 intrinsically safe Ex I, IP 68 for combination with HART module 4... 20mA current output Measurement length “M el. = 800mm, resolution 5mm Tmax 150°C - HART converter module 37384 intrinsically safe Ex i in the IP65 terminal box - 46307-02 mounting plate for HART module - Functional test (including hydrostatic pressure test) confirmed with factory certificate EN 10204:2004-2 .2 |